The installation begins by fitting the starter motor dust shield. After that, place and tighten the starter assembly onto the transmission. Secure the starter using the bolts and bracket for the electrical wiring and fasten them to 54 Nm (40 ft. lbs.). Join the electrical terminal from the starter to the solenoid's terminal and use the
Battery Cable and nut to secure the solenoid stud, ensuring you tighten it to 11 Nm (97 in. lbs.). Afterward, place the left side
Catalytic Converter. Afterwards, attach the negative cable and screw it in place using 5 Nm (45 in. lbs.).